Products: 10
Current
FN 3420 ECOsine® Active Harmonic Filters (3-wire)
(30A to 100A UL recognized / 200A to 300A UL listed)

 

FN 3420 ECOsine® Active Harmonic Filters (3-wire)

 

  • Global or selective compensation of Harmonic currents up to the 50th order
  • Compensation of displacement power factor
  • Load balancing capability
  • Response time of less than 300 microseconds
  • Compact solution for easy installation and intuitive operation
  • Compensation current: 30 to 300 A
  • Frequency: 47 to 63 Hz
  • THID: < 5%,adjustable
  • Voltage: 200 to 480 V
  •  
  •  
  •  
  •  
FN 3416 ECOsine® 50Hz Passive Harmonic Filters

 

FN 3416 ECOsine® 50Hz Passive Harmonic Filters

 

  • Economy line of passive harmonic
  • filters for THID <10 %
  • Help to comply with EN61000-3-12, IEEE-519 and other PQ standards
  • Support an efficient utilization of electrical system capacity
  • Ideal for motor drives with 6-pulse rectifier front-end
  • Suitable for diode and thyristor (SCR) rectifiers applications
  • THID: < 10%
  •  
FN 3418 ECOsine® 60Hz Passive Harmonic Filters

 

FN 3418 ECOsine® 60Hz Passive Harmonic Filters

 

  • Economy line of passive harmonic filters for THID <10 %
  • Help to comply with EN61000-3-12, IEEE-519 and other PQ standards
  • Support an efficient utilization of electrical system capacity
  • Ideal for motor drives with 6-pulse rectifier front-end
  • Suitable for diode and thyristor (SCR) rectifiers applications
  • THID: < 10%
  •  
FN 3410 ECOsine® 50 Hz Passive Harmonic Filters

 

FN 3410 ECOsine® 50 Hz Passive Harmonic Filters

 

  • The industry standard for 6-pulse rectifiers and motor drives
  • The most compact 5% THID filter available
  • Excellent behavior under partial load conditions
  • Filters for diode rectifiers
  • Frequency: 50 Hz
  • Rated Power: 4 to 200 kW
  • THID: < 5%
  • Voltage: 380 to 500 V
  •  
  •  
  •  
  •  
FN 3410 HV ECOsine® 50Hz Passive Harmonic Filters for 690V

 

FN 3410 HV ECOsine® 50Hz Passive Harmonic Filters for 690V

 

  • The industry standard for 6-pulse rectifiers and motor drives
  • The most compact 5% THID filter available
  • Excellent behavior under partial load conditions
  • Filters for diode rectifiers
  • Frequency: 50 Hz
  • Rated Power: 7.5 to 250 kW
  • THID: < 5%,~5% (with Ldc)
  • Voltage: 760 V
  • Voltage: 3 to 760 V
  •  
  •  
  •  
  •  
  •  
FN 3411 ECOsine® 50Hz Passive Harmonic Filters

 

FN 3411 ECOsine® 50Hz Passive Harmonic Filters

 

  • The industry standard for 6-pulse rectifiers and motor drives
  • Excellent behavior under partial load conditions
  • Filters for thyristor (SCR) rectifiers
  • Frequency: 50 Hz
  • THID: depending upon firing angle
  •  
  •  
FN 3412 ECOsine® 60 Hz Passive Harmonic Filters

 

FN 3412 ECOsine® 60 Hz Passive Harmonic Filters

 

  • The industry standard for 6-pulse rectifiers and motor drives
  • The most compact 5% THID filter available
  • Excellent behavior under partial load conditions
  • Filters for diode rectifiers
  • Frequency: 60 Hz
  • Rated Power: 5 to 250 HP
  • THID: < 5%
  • Voltage: 380 to 480 V
  •  
  •  
  •  
  •  
FN 3413 ECOsine® 60Hz Passive Harmonic Filters

 

FN 3413 ECOsine® 60Hz Passive Harmonic Filters

 

  • The industry standard for 6-pulse rectifiers and motor drives
  • Excellent behavior under partial load conditions
  • Filters for thyristor (SCR) rectifiers
  • Frequency: 60 Hz
  • THID: depending upon firing angle
  •  
  •  
FN 3430 ECOsine® Active Harmonic Filters (4-wire)

 

FN 3430 ECOsine® Active Harmonic Filters (4-wire)

 

  • Global or selective compensation of harmonic currents up to the 50th order
  • Compensation of displacement power factor
  • Load balancing capability
  • Response time of less than 300 microseconds
  • Compact solution for easy installation and intuitive operation
  • Compensation current: 30 to 300 A
  • Frequency: 47 to 63 Hz
  • THID: < 5%,adjustable
  • Voltage: 380 to 415 V
  •  
  •  
  •  
  •  
RWK 212 3-phase line reactor for motor drive applications
UL508C up to 400A. For use with AC or DC drives (power conversion equipment) only

 

RWK 212 3-phase line reactor for motor drive applications

 

  • Provision of 4% impedance
  • Reduction of mains harmonics
  • Reduction of commutation notches
  • Protection of motor drive electronics
  • Limitation of inrush currents
  • Improvement of true power factor
  • Frequency: 50 to 60 Hz
  • Impedance: 4 % @ 400 VAC, 50 Hz & rated current
  • Motor power: 1.5 to 630 kW
  • Rated Current: 4 to 1100 A
  • THID: appr. 40%
  • Voltage: ≤ 500 V
  •  
  •  
  •  
  •  
  •  
  •  

Inventory Search

Configurator

 -   V
Choose Voltage

more

Categories

Choose product by selecting a product category.

more

Delaware Alaska Rhode Islands Connecticut Massachusetts Maine New Hampshire Vermont New Jersey New York Maryland Pennsylvania West Virginia Virginia Ohio North Carolina South Carolina Michigan Indiana Kentucky Georgia Florida Alabama Tennessee Missisippi Illonis Wisconsin Loisana Arkansas Missouri Iowa Minnesota North Dakota South Dakota Nebraska Kansas Oklahoma Texas Montana Wyoming Colorado New Mexico Idaho Utah Arizona Nevada California Oregon Washinton

Featured Distributors

Contact Us

Schaffner EMC, Inc.

North America Headquarters

52 Mayfield Ave.

Edison, NJ 08837

P 1-800-367-5566
P 732-225-9533
F 732-225-4789
Click here to contact us